The garden tap
A hose in a bucket, and the backflow it can carry
A garden hose left in a container of liquid is one way WA says pollution can reach the drinking water supply. Two authorities say a small home connection needs no device of its own, two others require one where the hazard is medium or high, and where a state or territory’s page sets a test period for a testable device, it is every 12 months.
General information only: the water authority or council linked for your own property is the one that decides what it needs.
Guide 5 of 7.
What backflow is, in three authorities’ words
Backflow means water in a supply plumbing system running the wrong way, which starts when the water delivery main is under less pressure than the plumbing inside the property, a condition known as back siphonage. A property’s drinking water supply can also be joined to a source of pollution by accident, through a cross connection, such as one from a bore pump pushing bore water at a higher pressure than the mains, or simply through a hose left sitting in a container of liquid. Central Coast Council defines a cross connection as any link joining drinking water to another supply that is not fit to drink, for example recycled water, wastewater or stored water.
The consequence is what makes the fitting matter. NT’s Power and Water Corporation puts it as plainly as any page in this guide: water that has already been used and may carry contamination can flow back into the drinking water supply, and finish up in a person’s glass, and a serious backflow event can harm a person’s health, or at the very worst, threaten their life. A backflow prevention device is a barrier with a single permitted direction of travel: water may pass out of the water main and into a property, and if it begins to move the wrong way, the device closes or diverts it.
When a home needs a device, and when another body has provided it
This is the part the authorities answer differently, and the difference turns on the size of the connection and the risk of what is on the property. Central Coast Council requires no device on water service connections of 20 mm and 25 mm that supply drinking water for a single residential dwelling rated as low hazard, but an accredited backflow plumber has to assess how the site rates for hazard. Water Corporation in WA reaches the same end from the meter’s side: new meters 20 mm and 25 mm in size come with integral dual check valves, so a property rated low risk, such as a residential-only address served solely by a metered connection of that size, already has enough backflow prevention.
Where the risk is higher, the device is not optional. WA classes backflow risk as low, medium or high: medium risk is any condition, device or practice that could endanger health, and high risk any that could cause death. The property’s initial rating is given at approval, and site-specific activity determines the final level, with certain commercial and industrial processes defaulting a property to high. Central Coast Council requires a device on any property where a plumber has found a medium or high hazard of backflow reaching the drinking water system.
Sydney Water goes further and makes the device universal on paper: every connection carrying drinking or recycled water has to keep containment protection against backflow, which lowers the risk the property poses to the supply, and owners must make sure the right device sits on their property’s water service. Owners of commercial or industrial premises, and every other property that runs an on-site process, have to bring in an accredited backflow plumber to rate the cross-connection hazard, or Sydney Water will mark the property high hazard.
Whichever rule applies, the device is not a householder’s fitting. WA says backflow prevention devices may be fitted only by a licensed plumbing contractor. Victoria defines backflow prevention work as mending, altering, maintaining, testing or commissioning a testable backflow prevention device named in the Australian Standard, and its plumber classes page lists the unit on commissioning and maintaining backflow prevention devices among the requirements to become registered or licensed in that class.
The yearly clock, authority by authority
Once a testable device is in, it is tested on a clock and registered with a body, and each authority sets its own periods.
- WA: testable devices at the boundary, on medium or high risk properties and fire services alike, must be tested when they are commissioned, after any maintenance, and once every 12 months, by an accredited tester; the registration goes in within 5 working days of the test, and only a licensed plumbing contractor may maintain them. The test report also goes in online, within 5 working days of the test.
- Queensland: the owner of premises must register the testable device with the local government in the approved form, and arrange for a backflow prevention licensee to maintain and test it at least once each year after it is registered. The Act also makes it an offence to remove a device or to do anything that makes it inoperable.
- The ACT: an owner with one or more devices must have them registered with Access Canberra at the time of installation and tested by a licensed plumber every 12 months. Only a licensed plumber endorsed to test devices can complete the report, and the plumber submits it to Access Canberra; the initial test is free and registering an annual test is $26.00 per report.
- Central Coast, NSW: every testable device there has to be tested once a year, with the results sent to the council, and the council charges no fee to lodge the yearly inspection and maintenance report. The council maintains a register of testable devices and monitors compliance; where a device does not comply it may issue a notice requiring repair, maintenance, testing or replacement.
- Sydney Water’s area: if the annual inspections at a property are not completed, Sydney Water may organise a plumber and charge the owner for the service.
- The NT: an owner of a business or multi-dwelling may be required to have a device and to have it tested every year; a backflow accredited plumber assesses the hazard level, and any property rated medium or high risk has to have a testable device fitted.
The garden tap, and the hose
The garden tap is where a householder’s own work runs closest to this. Queensland’s unregulated list includes installing or maintaining an irrigation or lawn watering system downstream from a tap, isolating valve or backflow prevention device on the supply pipe for the watering system, so that side of the device is a householder’s. The device and the supply side of it are the plumber’s, and the reason is the hose’s own habit: the example WA gives for a cross connection is a hose submerged in a container of liquid, and the pollution it carries can enter the water supply when the pressure drops.
The hose is not the only quiet cross connection. The ACT’s list of where devices are typically installed runs from large commercial buildings such as offices, apartment complexes, universities, schools and hospitals to anywhere there is a medium to high risk of backflow occurring, such as an irrigation system or a rainwater tank connected to the main water supply.
Where practitioners cannot achieve the required height for an overflow relief gully, NSW allows a reflux valve as a substitute, with a condition attached about what is not installed upstream of it. And the community’s side of the bargain is stated by WA: people have a right to protection from contamination in their water when a backflow incident happens.
One device, one year, worked through
Take a house whose assessment comes back medium risk, in a state that follows WA’s pattern. The device goes in on the owner’s side of the water connection at the boundary, and devices should not be buried in the ground. It is tested at commissioning; when maintenance is done it is tested again; and it is tested every 12 months after that. Each test is followed within 5 working days by a report, the registration going to the water authority and the test report going in online. If the device fails or is not maintained, the authority’s remedy is a notice to the owner or occupier, and in WA a non-compliance notice follows a failure to maintain a device.
A property may also appeal a rating: WA allows an owner who considers the assigned risk rating higher than the site’s activities warrant to appeal within 28 days of being advised of the rating, with the outcome advised to the property owner. Water Corporation’s backflow pages are where that state sets it all out.